Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mol Biol Rep ; 49(12): 11795-11809, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36205855

RESUMO

BACKGROUND: Cardiomyocyte hypertrophy is a hallmark of cardiac dysfunction in patients with aortic stenosis (AS), and can be triggered by left ventricular (LV) pressure overload in mice by aortic banding (AB). Syndecan-4 is a transmembrane heparan sulphate proteoglycan which is found increased in the myocardium of AS patients and AB mice. The role of syndecan-4 in cardiomyocyte hypertrophy is not well understood. PURPOSE OF THE STUDY: We developed mice with cardiomyocyte-specific overexpression of syndecan-4 (Sdc4-Tg) and subjected these to AB to examine the role of syndecan-4 in hypertrophy and activation of the pro-hypertrophic calcineurin-NFAT signalling pathway. METHODS AND RESULTS: Sdc4-Tg mice showed exacerbated cardiac remodelling upon AB compared to wild type (WT). At 2-6 weeks post-AB, Sdc4-Tg and WT mice showed similar hypertrophic growth, while at 20 weeks post-AB, exacerbated hypertrophy and dysfunction were evident in Sdc4-Tg mice. After cross-breeding of Sdc4-Tg mice with NFAT-luciferase reporter mice, we found increased NFAT activation in Sdc4-Tg hearts after AB. Immunoprecipitation showed that calcineurin bound to syndecan-4 in Sdc4-Tg hearts. Isolated cardiomyocytes from Sdc4-Tg mice showed alterations in Ca2+ fluxes, suggesting that syndecan-4 regulated Ca2+ levels, and thereby, activating the syndecan-4-calcineurin complex resulting in NFAT activation and hypertrophic growth. Similarly, primary cardiomyocyte cultures from neonatal rats showed increased calcineurin-NFAT-dependent hypertrophic growth upon viral Sdc4 overexpression. CONCLUSION: Our study of mice with cardiomyocyte-specific overexpression of Sdc4 have revealed that syndecan-4 is important for activation of the Ca2+-dependent calcineurin-NFAT signalling pathway, hypertrophic remodelling and dysfunction in cardiomyocytes in response to pressure overload.


Assuntos
Calcineurina , Miócitos Cardíacos , Sindecana-4 , Animais , Camundongos , Ratos , Calcineurina/metabolismo , Cardiomegalia/genética , Cardiomegalia/metabolismo , Células Cultivadas , Miócitos Cardíacos/metabolismo , Fatores de Transcrição NFATC/metabolismo , Transdução de Sinais/fisiologia , Sindecana-4/genética , Sindecana-4/metabolismo
2.
PLoS One ; 16(3): e0247826, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33647070

RESUMO

Myocardial velocities carry important diagnostic information in a range of cardiac diseases, and play an important role in diagnosing and grading left ventricular diastolic dysfunction. Tissue Phase Mapping (TPM) Magnetic Resonance Imaging (MRI) enables discrete sampling of the myocardium's underlying smooth and continuous velocity field. This paper presents a post-processing framework for constructing a spatially and temporally smooth and continuous representation of the myocardium's velocity field from TPM data. In the proposed scheme, the velocity field is represented through either linear or cubic B-spline basis functions. The framework facilitates both interpolation and noise reducing approximation. As a proof-of-concept, the framework was evaluated using artificially noisy (i.e., synthetic) velocity fields created by adding different levels of noise to an original TPM data. The framework's ability to restore the original velocity field was investigated using Bland-Altman statistics. Moreover, we calculated myocardial material point trajectories through temporal integration of the original and synthetic fields. The effect of noise reduction on the calculated trajectories was investigated by assessing the distance between the start and end position of material points after one complete cardiac cycle (end point error). We found that the Bland-Altman limits of agreement between the original and the synthetic velocity fields were reduced after application of the framework. Furthermore, the integrated trajectories exhibited consistently lower end point error. These results suggest that the proposed method generates a realistic continuous representation of myocardial velocity fields from noisy and discrete TPM data. Linear B-splines resulted in narrower limits of agreement between the original and synthetic fields, compared to Cubic B-splines. The end point errors were also consistently lower for Linear B-splines than for cubic. Linear B-splines therefore appear to be more suitable for TPM data.


Assuntos
Técnicas de Imagem Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Miocárdio , Animais , Ratos , Ratos Wistar
3.
Am J Physiol Heart Circ Physiol ; 320(2): H912-H922, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33337965

RESUMO

Magnetic resonance imaging (MRI) of the right ventricle (RV) offers important diagnostic information, but the accuracy of this information is hampered by the complex geometry of the RV. Here, we propose a novel postprocessing algorithm that corrects for partial-volume effects in the analysis of standard MRI cine images of RV mass (RVm) and evaluate the method in clinical and preclinical data. Self-corrected RVm measurement was compared with conventionally measured RVm in 16 patients who showed different clinical indications for cardiac MRI and in 17 Wistar rats with different degrees of pulmonary congestion. The rats were studied under isoflurane anaesthesia. To evaluate the reliability of the proposed method, the measured end-systolic and end-diastolic RVm were compared. Accuracy was evaluated by comparing preclinical RVm to ex vivo RV weight (RVw). We found that use of the self-correcting algorithm improved reliability compared with conventional segmentation. For clinical data, the limits of agreement (LOAs) were -1.8 ± 8.6g (self-correcting) vs. 5.8 ± 7.8g (conventional), and coefficients of variation (CoVs) were 7.0% (self-correcting) vs. 14.3% (conventional). For preclinical data, LOAs were 21 ± 46 mg (self-correcting) vs. 64 ± 89 mg (conventional), and CoVs were 9.0% (self-correcting) and 17.4% (conventional). Self-corrected RVm also showed better correspondence with the ex vivo RVw: LOAs were -5 ± 80 mg (self-correcting) vs. 94 ± 116 mg (conventional) in end-diastole and -26 ± 74 mg (self-correcting) vs. 31 ± 98 mg (conventional) in end-systole. The new self-correcting algorithm improves the reliability and accuracy of RVm measurements in both clinical and preclinical MRI. It is simple and easy to implement and does not require any additional MRI data.NEW & NOTEWORTHY Magnetic resonance imaging (MRI) of the right ventricle (RV) offers important diagnostic information, but the accuracy of this information is hampered by the complex geometry of the RV. In particular, the crescent shape of the RV renders it particularly vulnerable to partial-volume effects. We present a new, simple, self-correcting algorithm that can be applied to correct partial-volume effects in MRI-based RV mass estimation. The self-correcting algorithm offers improved reliability and accuracy compared with the conventional approach.


Assuntos
Algoritmos , Cardiopatias/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Remodelação Ventricular , Animais , Modelos Animais de Doenças , Cardiopatias/fisiopatologia , Humanos , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Ratos Wistar , Reprodutibilidade dos Testes
4.
PLoS One ; 14(7): e0218874, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31276508

RESUMO

INTRODUCTION: Tissue Phase Mapping (TPM) MRI can accurately measure regional myocardial velocities and strain. The lengthy data acquisition, however, renders TPM prone to errors due to variations in physiological parameters, and reduces data yield and experimental throughput. The purpose of the present study is to examine the quality of functional measures (velocity and strain) obtained by highly undersampled TPM data using compressed sensing reconstruction in infarcted and non-infarcted rat hearts. METHODS: Three fully sampled left-ventricular short-axis TPM slices were acquired from 5 non-infarcted rat hearts and 12 infarcted rat hearts in vivo. The datasets were used to generate retrospectively (simulated) undersampled TPM datasets, with undersampling factors of 2, 4, 8 and 16. Myocardial velocities and circumferential strain were calculated from all datasets. The error introduced from undersampling was then measured and compared to the fully sampled data in order to validate the method. Finally, prospectively undersampled data were acquired and compared to the fully sampled datasets. RESULTS: Bland Altman analysis of the retrospectively undersampled and fully sampled data revealed narrow limits of agreement and little bias (global radial velocity: median bias = -0.01 cm/s, 95% limits of agreement = [-0.16, 0.20] cm/s, global circumferential strain: median bias = -0.01%strain, 95% limits of agreement = [-0.43, 0.51] %strain, all for 4x undersampled data at the mid-ventricular level). The prospectively undersampled TPM datasets successfully demonstrated the feasibility of method implementation. CONCLUSION: Through compressed sensing reconstruction, highly undersampled TPM data can be used to accurately measure the velocity and strain of the infarcted and non-infarcted rat myocardium in vivo, thereby increasing experimental throughput and simultaneously reducing error introduced by physiological variations over time.


Assuntos
Coração/diagnóstico por imagem , Coração/fisiologia , Imagem Cinética por Ressonância Magnética/métodos , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/fisiopatologia , Algoritmos , Animais , Simulação por Computador , Técnicas de Diagnóstico Cardiovascular/estatística & dados numéricos , Testes de Função Cardíaca/instrumentação , Testes de Função Cardíaca/métodos , Imagem Cinética por Ressonância Magnética/estatística & dados numéricos , Masculino , Miocárdio/patologia , Ratos Wistar , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia
5.
Am J Physiol Lung Cell Mol Physiol ; 316(6): L999-L1012, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30908936

RESUMO

Lung diseases with hypoxia are complicated by pulmonary hypertension, leading to heart failure and death. No pharmacological treatment exists. Increased proinflammatory cytokines are found in hypoxic patients, suggesting an inflammatory pathogenesis. Caspase-1, the effector of the inflammasome, mediates inflammation through activation of the proinflammatory cytokines interleukin (IL)-18 and IL-1ß. Here, we investigate inflammasome-related mechanisms that can trigger hypoxia-induced pulmonary hypertension. Our aim was to examine whether caspase-1 induces development of hypoxia-related pulmonary hypertension and is a suitable target for therapy. Wild-type (WT) and caspase-1-/- mice were exposed to 10% oxygen for 14 days. Hypoxic caspase-1-/- mice showed lower pressure and reduced muscularization in pulmonary arteries, as well as reduced right ventricular remodeling compared with WT. Smooth muscle cell (SMC) proliferation was reduced in caspase-1-deficient pulmonary arteries and in WT arteries treated with a caspase-1 inhibitor. Impaired inflammation was shown in hypoxic caspase-1-/- mice by abolished pulmonary influx of immune cells and lower levels of IL-18, IL-1ß, and IL-6, which were also reduced in the medium surrounding caspase-1 abrogated pulmonary arteries. By adding IL-18 or IL-1ß to caspase-1-deficient pulmonary arteries, SMC proliferation was retained. Furthermore, inhibition of both IL-6 and phosphorylated STAT3 reduced proliferation of SMC in vitro, indicating IL-18, IL-6, and STAT3 as downstream mediators of caspase-1-induced SMC proliferation in pulmonary arteries. Caspase-1 induces SMC proliferation in pulmonary arteries through the caspase-1/IL-18/IL-6/STAT3 pathway, leading to pulmonary hypertension in mice exposed to hypoxia. We propose that caspase-1 inhibition is a potential target for treatment of pulmonary hypertension.


Assuntos
Caspase 1/genética , Hipóxia Celular/fisiologia , Hipertensão Pulmonar/patologia , Miócitos de Músculo Liso/fisiologia , Função Ventricular Direita/fisiologia , Animais , Linhagem Celular , Proliferação de Células/genética , Humanos , Inflamassomos/metabolismo , Interleucina-18/metabolismo , Interleucina-1beta/metabolismo , Interleucina-6/metabolismo , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Músculo Liso Vascular/citologia , Músculo Liso Vascular/crescimento & desenvolvimento , Artéria Pulmonar/citologia , Artéria Pulmonar/patologia , Fator de Transcrição STAT3/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...